Model No. - Indoor
ART90TUAJ
Model No. - Outdoor
AOT90TPC3L
Reverse Cycle System
Yes
Optional Simple Wired RC
UTB-TPB
Optional Remote Sensor
UTD-RS100
Cooling Capacity (Watts)
26400
Cooling Capacity (BTU/h)
87000
Heating Capacity (Watts)
29500
Heating Capacity (BTU/h)
100000
Power Supply (Watts)
415
Phase-Frequency (Ph - Hz)
3-50
Power Supply Attachment
Indoor & Outdoor
Running Current, Cooling (Amps)
19.5
Running Current, Heating (Amps)
19.5
Input, Cooling (Watts)
10100
Input, Heating (Watts)
10100
Moisture Removal (l/hr)
7.5
E.E.R. - Cooling
2.61
C.O.P. - Heating
2.92
Fan Speed
1
Ex Static Pressure Range (Pa)
100 to 300
Air Circulation, High (l/s)
1200@200Pa
Compressor Type
Scroll
Dimensions - Inside Unit (HxWxD mm)
450x1550x700
Weight - Inside Unit (kg)
85
Dimensions - Outside Unit (HxWxD mm)
1380x1300x650
Weight - Outside Unit (kg)
245
Duct Work Plenum Size, Supply (mm)
1200 x 350
Duct Work Plenum Size, Return (mm)
1250 x 370
I.U. Sound Pressure Level (dBA@1mtr)
50
O.U. Sound Pressure Level (dBA@1mtr)
59
O.U. Sound Power Level (dBA)
70
Refrigerant Type
R407C
Connection Pipe Sizes, Gas (mm)
28.58
Connection Pipe Sizes, Liquid (mm)
12.7
Pre Charged Length (Metre)
30
Minimum Pipe Length (Metre)
5
Maximum Pipe Length (Metre)
50
Maximum Pipe Height (Metre)
30
Pipe Connection Methods
Flare & Flange
Outdoor operating Temp, Cooling Degrees C
0 to 46
Outdoor operating Temp, Heating Degrees C
-10 to 21

 
Features Glossary

Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.
Auto-Changeover
The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.
Program Timer
This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.
Weekly + setback Timer
Weekly + Setback timer can set temperature for two time spans and for each day of the week.
Fresh air intake
Fresh air can be taken in by a fan which can be connected using UTD-ECS5A* (optional parts). *Selected ducted units only
Control Port