> > > AUTA54LCLU
Model No. - Indoor
AUTA54LCLU
Model No. - Outdoor
AOTD54LATT
Cooling Capacity (Watts)
14,000
Cooling Capacity (BTU/h)
47,800
Range (Watts)
5,400~16,000
Range (BTU/h)
18,400~ 54,600
Heating Capacity (Watts)
16,000
Heating Capacity (BTU/h)
54,600
Range (Watts)
5,800~18,000
Range (BTU/h)
19,800 ~ 61,400
Phase-Frequency (Ph - Hz)
3-50
Power Supply Attachment
Outdoor
Running Current, Cooling (Amps)
6.2
Running Current, Range (Amps)
Max 9.9
Running Current, Heating (Amps)
6.3
Running Current, Range (Amps)
Max 9.9
Input, Cooling (Watts)
4,360
Input, Range (Watts)
Max 6480
Input, Heating (Watts)
4,430
Input, Range (Watts)
Max 6480
Moisture Removal (l/hr)
5.0
Air Circulation, High (l/s)
560
Compressor Type
DC Twin Rotary
Dimensions - Inside Unit (HxWxD mm)
288(50)x840(950)x840(950) (Grill)
Weight - Inside Unit (kg)
27(5.5) (Grill)
Dimensions - Outside Unit (HxWxD mm)
1290x900x330
Weight - Outside Unit (kg)
107
I.U. Sound Pressure Level (dBA@1mtr)
47
O.U. Sound Pressure Level (dBA@1mtr)
37
O.U. Sound Power Level (dBA)
70
Connection Pipe Sizes, Gas (mm)
15.88
Connection Pipe Sizes, Liquid (mm)
9.52
Pre Charged Length (Metre)
30
Minimum Pipe Length (Metre)
5
Maximum Pipe Length (Metre)
75
Maximum Pipe Height (Metre)
30
Pipe Connection Methods
Flare
Outdoor operating Temp, Cooling Degrees C
-15 to 46
Outdoor operating Temp, Heating Degrees C
-15 to 24
Up/Down Swing Louvre
The up/down louvre automatically swings up and down.
Automatic Louvre
The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.
Auto Shut Louvre
The auto shut louvres close or open automatically when the unit stops or starts.
Automatic Air Flow Adjustment
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.
Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.
Auto-Changeover
The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.
Program Timer
This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.
Weekly + setback Timer
Weekly + Setback timer can set temperature for two time spans and for each day of the week.
Connectable Distributing Duct
Conditioned air can be distributed to adjacent areas by means of a distribution duct.
Connectable Fresh Air Duct
Allows introduction of fresh air to occupied space.
|