Inverter Wall Mounted
Displaying 1 of 4
< Previous | Next >
ASTG24LFCB - 6.8kW(C)/8.0kW(H)



Feature Glossary    Download: Operating Manual (1 MB)
Specifications
Model No. - Indoor
ASTG24LFCB
Model No. - Outdoor
AOTG24LFLB
Reverse Cycle System
Yes
Cooling Capacity (Watts)
6800
Cooling Capacity (BTU/h)
23200
Range (Watts)
900-8300
Range (BTU/h)
3100-28300
Heating Capacity (Watts)
8000
Heating Capacity (BTU/h)
27300
Range (Watts)
900-10600
Range (BTU/h)
3100-36200
Power Supply (Volts)
240
Phase-Frequency (Ph - Hz)
1-50
Power Supply Attachment
Outdoor
Plug Size (If Applicable)
NA
Running Current, Cooling (Amps)
8.6
Running Current, Range (Amps)
Max 13.5
Running Current, Heating (Amps)
9.5
Running Current, Range (Amps)
Max 18.5
Input, Cooling (Watts)
2040
Input, Range (Watts)
300-3210
Input, Heating (Watts)
2260
Input, Range (Watts)
280-4400
Moisture Removal (l/hr)
2.7
E.E.R. - Cooling
3.33
C.O.P. - Heating
3.54
Star Rating - Cooling
2
Star Rating - Heating
2.5
Fan Speed
4
Air Circulation, High (l/s)
306
Compressor Type
Rotary
Dimensions - Inside Unit (HxWxD mm)
320x998x238
Weight - Inside Unit (kg)
14
Dimensions - Outside Unit (HxWxD mm)
578x790x315
Weight - Outside Unit (kg)
43
I.U. Sound Pressure Level (dBA@1mtr)
47
O.U. Sound Pressure Level (dBA@1mtr)
53
O.U. Sound Power Level (dBA)
71
Refrigerant Type
R410A
Connection Pipe Sizes, Gas (mm)
15.88
Connection Pipe Sizes, Liquid (mm)
6.35
Pre Charged Length (Metre)
15
Minimum Pipe Length (Metre)
3
Maximum Pipe Length (Metre)
30
Maximum Pipe Height (Metre)
20
Pipe Connection Methods
Flare
Outdoor operating Temp, Cooling Degrees C
-10 to 46
Outdoor operating Temp, Heating Degrees C
-15 to 24

 
Features Glossary

Cooling

Heating

Up/Down Swing Louvre
The up/down louvre automatically swings up and down.
Right/Left Swing Louvre
The right/left louvre automatically swings in either direction.
Double Swing Automatic
Complex swing action of the louvres enables them to swing automatically in both horizontal and vertical directions.
Automatic Louvre
The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.
Auto Shut Louvre
The auto shut louvres close or open automatically when the unit stops or starts.
Automatic Air Flow Adjustment
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.
Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.
Auto-Changeover
The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.
Sleep Timer
The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.
Program Timer
This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.
ON-OFF Timer
ON-OFF timer can be set to operate once every 24 hours.
ALL DC
With All DC, electricity loss is decreased and power consumption reduced.
Washable Panel

Long-life* Ion deodorisation filter
The filter deodorises by powerfully decomposing absorbed odours using the oxidizing filter and reducing effects of ions generated by the ultra-fine-particle ceramic. (*The filter can be used for approximately 3 years if it is washed under water to restore its surface action when it is dirty.)
Apple-catechin filter
Fine dust, invisible mold spores and harmful micro-organisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.
Economy mode
Limits the maximum operation current, and performs operation with the power consumption suppressed.
Filter sign
Indicates the filter cleaning period by lamp.
Control Port
External inputs and outputs contained within the product allow on/off control, fresh air interlock connection and heater bank element connection. UTD-ECS5A* (optional parts). * Selected ducted units only.
Blue Fin Heat Exchanger
Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchange.