Products > Air Conditioning > Multi Type System > ARTG18LLTA-AOTG30LAT4
Inverter Multi - Ducted
Displaying 6 of 6
< Previous | Next >
ARTG18LLTA with AOTG30LAT4



Feature Glossary    Download: Operating Manual (2 MB)
Specifications
Model No. - Indoor
ARTG18LLTA
Model No. - Outdoor
AOTG30LAT4
Reverse Cycle System
Yes
Capacity Class
5
Cooling Capacity (Watts)
5,200
Cooling Capacity (BTU/h)
17,758
Range (Watts)
6,000
Range (BTU/h)
20,491
Heating Capacity (Watts)
6,000
Heating Capacity (BTU/h)
20,491
Range (Watts)
7,100
Range (BTU/h)
24,247
Power Supply (Volts)
240
Phase-Frequency (Ph - Hz)
1-50
Power Supply Attachment
Outdoor
Plug Size (If Applicable)
NA
Running Current (Amps)
0.44
Input (Watts)
73
Fan Speed
4
Air Circulation, High (l/s)
261
Compressor Type
Twin Rotary
Dimensions - Inside Unit (HxWxD mm)
198x900x330
Weight - Inside Unit (kg)
68
Dimensions - Outside Unit (HxWxD mm)
830x900x330
Weight - Outside Unit (kg)
68
I.U. Sound Pressure Level (dBA@1mtr)
32
O.U. Sound Pressure Level (dBA@1mtr)
50
O.U. Sound Power Level (dBA)
64
Refrigerant Type
R410A
Connection Pipe Sizes, Gas (mm)
12.7
Connection Pipe Sizes, Liquid (mm)
6.35
Minimum Pipe Length (Metre)
5
Maximum Pipe Length (Metre)
25
Maximum Pipe Height (Metre)
10
Pipe Connection Methods
Flare
Outdoor operating Temp, Cooling Degrees C
0 to 46
Outdoor operating Temp, Heating Degrees C
-10 to 24

 
Features Glossary

Cooling

Heating

Automatic Air Flow Adjustment
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.
Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.
Sleep Timer
The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.
ON-OFF Timer
ON-OFF timer can be set to operate once every 24 hours.
Weekly Timer
Different on-off times can be set for up to 7 days.
ALL DC
With All DC, electricity loss is decreased and power consumption reduced.
Weekly + setback Timer
Weekly + Setback timer can set temperature for two time spans and for each day of the week.
Connectable Distributing Duct
Conditioned air can be distributed to adjacent areas by means of a distribution duct.
Fresh air intake
Fresh air can be taken in by a fan which can be connected using UTD-ECS5A* (optional parts). *Selected ducted units only
Economy mode
Limits the maximum operation current, and performs operation with the power consumption suppressed.
Control Port
External inputs and outputs contained within the product allow on/off control, fresh air interlock connection and heater bank element connection. UTD-ECS5A* (optional parts). * Selected ducted units only.
Indoor Unit Connectability
This indoor unit can be connected to a multi-type outdoor unit depending on model.