Inverter Wall Mounted
Displaying 1 of 3
< Previous | Next >
ASTA09LCC



Feature Glossary    Download: Operating Manual (420.37 KB)
Specifications
Model No. - Indoor
ASTA09LCC
Model No. - Outdoor
AOTR09LCC
Reverse Cycle System
Yes
Cooling Capacity (Watts)
2600
Cooling Capacity (BTU/h)
8900
Range (Watts)
500-3600
Range (BTU/h)
1700-12300
Heating Capacity (Watts)
3600
Heating Capacity (BTU/h)
12300
Range (Watts)
500-5300
Range (BTU/h)
1700-18100
Power Supply (Watts)
240
Phase-Frequency (Ph - Hz)
1-50
Power Supply Attachment
Indoor
Plug Size (If Applicable)
10 amp plug
Running Current, Cooling (Amps)
3
Running Current, Range (Amps)
Max 6
Running Current, Heating (Amps)
3.9
Running Current, Range (Amps)
Max 8.5
Input, Cooling (Watts)
655
Input, Range (Watts)
250-1380
Input, Heating (Watts)
845
Input, Range (Watts)
250-1960
Moisture Removal (l/hr)
1.3
E.E.R. - Cooling
3.963
C.O.P. - Heating
4.261
Star Rating - Cooling
3
Star Rating - Heating
3.5
Fan Speed
4
Air Circulation, High (l/s)
165
Compressor Type
Rotary
Dimensions - Inside Unit (HxWxD mm)
275x790x215
Weight - Inside Unit (kg)
9
Dimensions - Outside Unit (HxWxD mm)
540x660x290
Weight - Outside Unit (kg)
32
I.U. Sound Pressure Level (dBA@1mtr)
41
O.U. Sound Pressure Level (dBA@1mtr)
48
O.U. Sound Power Level (dBA)
65
Refrigerant Type
R410A
Connection Pipe Sizes, Gas (mm)
9.52
Connection Pipe Sizes, Liquid (mm)
6.35
Pre Charged Length (Metre)
15
Minimum Pipe Length (Metre)
3
Maximum Pipe Length (Metre)
20
Maximum Pipe Height (Metre)
15
Pipe Connection Methods
Flare
Outdoor operating Temp, Cooling Degrees C
10 to 43
Outdoor operating Temp, Heating Degrees C
-15 to 24

 
Features Glossary

Up/Down Swing Louvre
The up/down louvre automatically swings up and down.
Right/Left Swing Louvre
The right/left louvre automatically swings in either direction.
Automatic Louvre
The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.
Auto Shut Louvre
The auto shut louvres close or open automatically when the unit stops or starts.
Automatic Air Flow Adjustment
When auto mode is selected for the fan, the micro-processor adjusts the airflow to follow changes in room temperature.
Auto Restart
Should there be temporary loss of power; the unit will automatically restart itself in the same operating mode, once the power is restored.
Auto-Changeover
The unit automatically switches between heating and cooling modes based on the temperature setting and room temperature.
Sleep Timer
The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.
Program Timer
This timer allows selection of one of four options. ON, OFF, ON > OFF, or OFF > ON.
Washable Panel

Apple-catechin filter
Fine dust, invisible mold spores and harmful micro-organisms are absorbed onto the filter by static electricity and further growth is inhibited and deactivated by the polyphenol ingredient extracted from apples.
Long-life* Ion deodorisation filter
The filter deodorises by powerfully decomposing absorbed odours using the oxidizing filter and reducing effects of ions generated by the ultra-fine-particle ceramic. (*The filter can be used for approximately 3 years if it is washed under water to restore its surface action when it is dirty.)