Slimline Plus Ducted
Available in Reverse Cycle - 7.1kW, 8.5kW, 10.0kW, 11.5kW, 13.0kW
Refrigerant R410A

Warranty Information

Download our warranty card to read about our 5 year warranty

View Warranty Info

Key features

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Connectable Fresh Air Duct
    Connectable Fresh Air Duct

    Allows introduction of fresh air to the occupied space.

  • Connectable Distribution Duct
    Connectable Distributing Duct

    Systems are capable of attaching a field-supplied branch ducts distributing the airflow.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Filter Sign
    Filter Sign

    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • Fresh Air Intake
    Fresh Air Intake

    Fresh air can be taken in by a fan which can be connected using an external control unit.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

Technical Specifications

Attribute ARTG24LHTDP 7.10kW(C) 8.00kW(H) View model ARTG30LHTDP 8.50kW(C) 10.00kW(H) View model ARTG36LHTDP 10.00kW(C) 11.20kW(H) View model ARTG45LHTDP 11.50kW(C) 14.00kW(H) View model ARTG54LHTDP 13.00kW(C) 16.00kW(H) View model
Operation Type
Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz
230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max))
7.10 (2.9 - 8.0) 8.50 (2.8 - 10.0) 10.00 (3.8 - 11.2) 11.50 (4.0 - 13.3) 13.00 (6.2 - 15.2)
Heating Capacity kW (Rated (Min - Max))
8.00 (2.2 - 9.1) 10.00 (2.7 - 11.2) 11.20 (4.0 - 14.0) 14.00 (4.2 - 15.5) 16.00 (6.2 - 18.0)
Input Power Cooling kW (Rated (Max))
2.08 (4.06) 2.65 (4.06) 3.11 (4.78) 3.33 (5.00) 3.92 (5.58)
Input Power Heating kW (Rated (Max))
2.19 (4.40) 2.7 (4.06) 3.07 (4.76) 3.68 (5.02) 4.45 (5.59)
EER Cooling kW/kW
3.41 3.21 3.22 3.45 3.32
COP Heating kW/kW
3.65 3.70 3.65 3.80 3.60
Star Rating Cooling (0-10) (Hot / Average / Cold)
3.0 / 2.5 / 3.0 2.5 / 2.0 / 2.5 2.5 / 2.5 / 2.5 3.0 / 2.5 / 3.0 3.0 / 2.5 / 2.5
Star Rating Heating (0-10) (Hot / Average / Cold)
2.5 / 2.0 / 1.5 2.5 / 2.0 / 1.5 2.5 / 2.0 / 1.5 2.5 / 2.0 / 1.5 2.5 / 2.0 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.790 / 4.475 / 4.673 4.142 / 3.899 / 4.024 4.45 / 4.197 / 4.388 4.635 / 4.367 / 4.539 4.535 / 4.287 / 4.476
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.448 / 3.679 / 3.022 4.335 / 3.921 / 3.469 4.429 / 3.765 / 3.161 4.379 / 3.898 / 3.354 4.224 / 3.644 / 3.092
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
5.145 / 5.274 / 5.657 4.404 / 4.46 / 4.743 4.762 / 4.884 / 5.236 4.946 / 5.044 / 5.387 4.845 / 4.962 / 5.313
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.452 / 3.826 / 3.320 4.334 / 4.082 / 3.699 4.433 / 4.045 / 3.409 4.376 / 4.072 / 3.636 4.224 / 3.741 / 3.307
Running Current amps (Cooling / Heating)
8.7 / 9.2 11.1 / 11.3 13.0 / 12.9 14.0 / 15.4 16.5 / 18.7
Moisture Removal l/hr
2.2 2.3 2.4 2.6 3.7
Indoor Sound Pressure Cooling dBA (High / Quiet)
33 / 21 37 / 29 36 / 26 40 / 29 40 / 29
Indoor Sound Pressure Heating dBA (High / Quiet)
33 / 21 37 / 29 33 / 26 40 / 29 40 / 29
Outdoor Sound Pressure dBA (Cooling / Heating)
55 / 56 53 / 55 54 / 55 55 / 55 55 / 57
Outdoor Sound Power dBA
69 69 70 69 70
Static Pressure Range PA (Min to Max)
30 to 200 30 to 200 30 to 200 30 to 200 30 to 200
Air Circulation (Indoor - High Fan) Cooling l/sec
378 472 569 708 708
Air Circulation (Indoor - High Fan) Heating l/sec
378 478 514 708 708
Indoor Unit Dimensions mm (Height x Width x Depth)
300 x 1000 x 700 300 x 1000 x 700 300 x 1400 x 700 300 x 1400 x 700 300 x 1400 x 700
Indoor Unit Weight kg
36.00 36.00 46.00 46.00 46.00
Outdoor Unit Dimensions mm (Height x Width x Depth)
620 x 790 x 290 830 x 900 x 330 830 x 900 x 330 1290 x 900 x 330 1290 x 900 x 330
Outdoor Unit Weight kg
41.00 61.00 61.00 86.00 93.00
Piping Connects mm Ø (Liquid / Gas)
6.35 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Pipe Length m (Max (Precharged))
30 (15) 50 (20) 50 (20) 50 (20) 75 (30)
Max Height Difference m
20 30 30 30 30
Operation Range Cooling °CDB (Min to Max)
-10 to 46 -15 to 46 -15 to 46 -15 to 46 -15 to 46
Operation Range Heating °CDB (Min to Max)
-15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24
Refrigerant Type
R410A R410A R410A R410A R410A
Refrigerant Amount g
1,800 2,100 2,100 3,350 3,450
Commercial Call To Action

Find a commercial authorised partner

map-icon-white Find a Stockist

COMMERCIAL CASE STUDIES

Here are a few examples showcasing Fujitsu General's commercial capabilities.

1 telopea place
Jacfin PTY LTD, Vaughan Constructions

1 Telopea Place, Eastern Creek

View Case Study
lotus tower
Place Projects

Lotus Tower

View Case Study
ESCA / MDLR Pty Ltd

ESCA, Inman Valley, SA

View Case Study
METRO AIR

McDonalds

View Case Study

This product is part of Light Commercial

Back to Light Commercial