Mid Static Slimline R32
Available in Reverse Cycle - 7.1kW, 8.5kW
Refrigerant R32

Download our brochure

Download or view the brochure in a PDF by clicking below

Download PDF

Warranty Information

Download our warranty card to read about our 5 year warranty

View Warranty Info

Key features

  • Long Piping Capability 75m

    This product is equipped with a maximum pipe length of 75m.

  • Demo Mode

    This function allows the indoor unit to be operated alone at exhibitions and showrooms.

  • Operating Temperature Range 50°C

    The maximum guaranteed operating temperature range to 50 degrees in cooling mode.

  • In-Built drain pump
    In-Built Drain Pump

    The drain pump is in-built into the system.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Filter Sign
    Filter Sign

    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Demand Response

    This product is designed to be compatible with Air Conditioning Demand Response program. When your electricity supplier activates one of the three modes the air conditioner switches over to the appropriate operation.

  • Connectable Distribution Duct
    Connectable Distributing Duct

    Systems are capable of attaching a field-supplied branch ducts distributing the airflow.

  • Connectable Fresh Air Duct
    Connectable Fresh Air Duct

    Allows introduction of fresh air to the occupied space.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Zone Control
    Zone Control

    This function enables efficient air-conditioning by selecting specific zones from the various zones divided within the indoor space.

Technical Specifications

Attribute ARTH24KMTAP-HP 7.10kW(C) 8.00kW(H) View model ARTH30KMTAP-HP 8.50kW(C) 10.00kW(H) View model
Operation Type
Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz
230 / 1 / 50 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max))
7.10 (3.3 - 8.5) 8.50 (4.1 - 10.5)
Heating Capacity kW (Rated (Min - Max))
8.00 (3.6 - 10.5) 10.00 (4.2 - 11.5)
Input Power Cooling kW (Rated (Max))
1.85 (2.72) 2.26 (3.38)
Input Power Heating kW (Rated (Max))
1.93 (2.89) 2.47 (3.12)
EER Cooling kW/kW
3.84 3.76
COP Heating kW/kW
4.15 4.05
Star Rating Cooling (0-10) (Hot / Average / Cold)
3 / 2.5 / 2.5 3.5 / 2.5 / 2
Star Rating Heating (0-10) (Hot / Average / Cold)
3 / 2.5 / 3 3 / 3 / 3
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.712 / 4.474 / 4.598 4.8 / 4.569 / 4.727
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.962 / 4.491 / 4.043 5.036 / 4.472 / 3.899
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.976 / 5.005 / 5.302 5.084 / 5.154 / 5.481
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.964 / 4.288 / 4.679 5.043 / 4.702 / 4.207
Running Current amps (Cooling / Heating)
8 / 8.4 9.6 / 10.5
Moisture Removal l/hr
1.7 1.6
Indoor Sound Pressure Cooling dBA (High / Quiet)
38 / 27 38 / 28
Indoor Sound Pressure Heating dBA (High / Quiet)
38 / 27 38 / 28
Outdoor Sound Pressure dBA (Cooling / Heating)
48 / 50 51 / 53
Outdoor Sound Power dBA
67 69
Static Pressure Range PA (Min to Max)
50 to 150 50 to 150
Air Circulation (Indoor - High Fan) Cooling l/sec
416.67 541.67
Air Circulation (Indoor - High Fan) Heating l/sec
416.67 541.67
Indoor Unit Dimensions mm (Height x Width x Depth)
240 x 1000 x 700 240 x 1400 x 700
Indoor Unit Weight kg
31.00 42.00
Outdoor Unit Dimensions mm (Height x Width x Depth)
988 x 940 x 320 998 x 940 x 320
Outdoor Unit Weight kg
63.00 64.00
Piping Connects mm Ø (Liquid / Gas)
6.35 / 12.7 9.52 / 15.88
Pipe Length m (Max (Precharged))
75 (30) 75 (30)
Max Height Difference m
30 30
Operation Range Cooling °CDB (Min to Max)
-10 to 50 -10 to 50
Operation Range Heating °CDB (Min to Max)
-15 to 24 -15 to 24
Refrigerant Type
R32 R32
Refrigerant Amount g
1,800 2,100
Commercial Call To Action

Find a commercial authorised partner

map-icon-white Find a Stockist

COMMERCIAL CASE STUDIES

Here are a few examples showcasing Fujitsu General's commercial capabilities.

ESCA / MDLR Pty Ltd

ESCA, Inman Valley, SA

View Case Study
METRO AIR

McDonalds

View Case Study
AUSTRALIAN TURF CLUB

Winx Stand

View Case Study
Glebe Tile
ZENPROP / EPIC AIR

St John Street Glebe

View Case Study

This product is part of Light Commercial

Back to Light Commercial