Cassette 4way Flow
Available in Reverse Cycle - 8.5kW, 10.0kW, 12.5kW, 14.0kW
Refrigerant R410A

Key features

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Automatic Air Flow Adjustment
    Automatic Air Flow Adjustment

    The micro-processor automatically adjusts the air flow to follow changes in room temperature.

  • Automatic Louvre
    Automatic Louvre

    The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Low Noise Mode
    Low Noise Mode

    The compressor speed and the outdoor unit fan speed are limited to reduce the operational noise.

  • i-PAM
    i-PAM

    i-PAM inverter technology enables high output and high efficiency performance.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Removable Intake Grill
    Removable Intake Grill

    The indoor unit’s intake grille can be removed for easy cleaning and maintenance.

  • Sleep Timer
    Sleep Timer

    The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

  • Super Quiet Mode
    Super Quiet Mode

    The indoor units fan can operate at a low speed to produce quieter operation.

  • v-PAM
    V-PAM

    v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

  • Washable Panel
    Washable Panel

    Dust that accumulates on the air conditioner can be easily cleaned with a damp cloth.

  • Weekly Setback Timer
    Weekly + Setback Timer

    Weekly + setback timer can set temperature for two time spans and for each day of the week.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

Download our brochure

Download or view the brochure in a PDF by clicking below

Download PDF

Take control. Controller options.

This range is compatible with the following controller options.

AR-SY1
  • controller-feature tick
    Low Noise Mode

    The compressor speed and the outdoor unit fan speed are limited to reduce the operational noise.

  • controller-feature tick
    Economy Mode

    The economy operation will save energy in heating, cooling and dry mode and is set by pressing the button on the remote control.

  • controller-feature tick
    Sleep Timer

    The micro processor gradually changes the room temperature allowing you to sleep comfortably at night.

UTY-LNHY
  • controller-feature tick
    Built-in Timers

    4 timer programs: On / Off / Program / Sleep Program timer: Operates ON/OFF timer once within 24 hours Sleep timer: Corrects the set temperature automatically during sleep time.

  • controller-feature tick
    Easy Installation and Operation

    Code selector switch prevents indoor unit mix-up (up to 4 codes). Wide and precise transmitting range.

  • controller-feature tick
    Touch Screen

    A user friendly backlit touch screen display assists with simple and easy operation.

  • controller-feature tick
    Backlit Display

    An illuminated display for improved visibiltiy and clairty. Brightness and light duration can be customised to suit your preferences.

  • controller-feature tick
    Sleep Timer

    The micro processor gradually changes the room temperature allowing you to sleep comfortably at night.

UTY-RSRY
  • controller-feature tick
    Large LCD

    Large LCD screen with simple operation buttons for ease of use.

  • controller-feature tick
    Backlit Display

    An illuminated display for improved visibiltiy and clairty. Brightness and light duration can be customised to suit your preferences.

  • controller-feature tick
    Built-in Room Temperature Sensor

    Monitors and controls room temperature accurately.

UTY-RHRY
  • controller-feature tick
    Large LCD

    Large LCD screen with simple operation buttons for ease of use.

  • controller-feature tick
    Backlit Display

    An illuminated display for improved visibiltiy and clairty. Brightness and light duration can be customised to suit your preferences.

  • controller-feature tick
    Built-in Room Temperature Sensor

    Monitors and controls room temperature accurately.

  • controller-feature tick
    ON-OFF Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • controller-feature tick
    Program Timer

    This timer allows selection of one of four options; ON, OFF, ON to OFF, or OFF to ON.

  • controller-feature tick
    Low Noise Mode

    The compressor speed and the outdoor unit fan speed are limited to reduce the operational noise.

Find the perfect model. Explore the Cassette 4-Way Flow range.

Technical Specifications

Attribute AUTA30LBLU 8.50kW(C) 10.00kW(H) View model AUTA36LCLU 10.00kW(C) 11.20kW(H) View model AUTA45LCLU 12.50kW(C) 14.00kW(H) View model AUTG54LRLA 14.00kW(C) 16.00kW(H) View model
Operation Type
Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz
240 / 1 / 50 240 / 1 / 50 240 / 1 / 50 400 / 3 / 50
Cooling Capacity kW (Rated (Min - Max))
8.50 (2.8 - 10.0) 10.00 (3.5 - 11.2) 12.50 (4.0 - 14.0) 14.00 (5.4 - 16.0)
Heating Capacity kW (Rated (Min - Max))
10.00 (2.7 - 11.2) 11.20 (4.0 - 14.0) 14.00 (4.2 - 16.2) 16.00 (5.8 - 18.0)
Input Power Cooling kW (Rated (Max))
2.57 (4.04) 2.94 (4.54) 3.89 (4.78) -
Input Power Heating kW (Rated (Max))
2.77 (4.04) 2.98 (4.54) 3.83 (4.78) -
EER Cooling kW/kW
3.31 3.40 3.21 3.21
COP Heating kW/kW
3.61 3.76 3.66 3.61
Star Rating Cooling (0-10) (Hot / Average / Cold)
2.5 / 2.0 / 2.0 3.0 / 2.5 / 3.0 2.5 / 2.5 / 2.5 2.5 / 2.5 / 2.5
Star Rating Heating (0-10) (Hot / Average / Cold)
3.0 / 2.5 / 1.5 3.5 / 2.5 / 2.0 3.0 / 2.0 / 1.5 2.5 / 2.0 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.216 / 3.874 / 3.956 4.835 / 4.454 / 4.638 4.497 / 4.191 / 4.370 4.392 / 4.024 / 4.153
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.961 / 4.003 / 3.143 5.017 / 4.347 / 3.738 4.813 / 3.982 / 3.292 4.498 / 3.773 / 3.142
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.503 / 4.519 / 4.787 5.216 / 5.337 / 5.724 4.831 / 4.947 / 5.303 4.728 / 4.798 / 5.119
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.980 / 4.371 / 3.624 5.033 / 4.630 / 4.094 4.826 / 4.161 / 3.597 4.505 / 4.082 / 3.413
Running Current amps (Cooling / Heating)
10.8 / 11.6 12.3 / 12.5 16.3 / 16.1 6.2 / 6.3
Moisture Removal l/hr
2.5 3.0 4.5 5.0
Indoor Sound Pressure Cooling dBA (High / Quiet)
40 / 32 44 / 33 46 / 36 47 / 37
Indoor Sound Pressure Heating dBA (High / Quiet)
40 / 32 44 / 33 46 / 36 47 / 37
Outdoor Sound Pressure dBA (Cooling / Heating)
53 / 55 54 / 54 55 / 55 55 / 56
Outdoor Sound Power dBA
69 68 69 70
Air Circulation (Indoor - High Fan) Cooling l/sec
444 500 528 556
Air Circulation (Indoor - High Fan) Heating l/sec
444 500 528 556
Indoor Unit Dimensions mm (Height x Width x Depth)
288 x 840 x 840 288 x 840 x 840 288 x 840 x 840 288 x 840 x 840
Indoor Unit Weight kg
26.00 27.00 27.00 26.00
Outdoor Unit Dimensions mm (Height x Width x Depth)
830 x 900 x 330 1290 x 900 x 330 1290 x 900 x 330 1290 x 900 x 330
Outdoor Unit Weight kg
61.00 86.00 86.00 104.00
Grill Dimensions mm (Height x Width x Depth)
50 x 950 x 950 50 x 950 x 950 50 x 950 x 950 50 x 950 x 950
Grill Weight kg
5.50 5.50 5.50 5.50
Piping Connects mm Ø (Liquid / Gas)
9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Pipe Length m (Max (Precharged))
50 (20) 50 (20) 50 (20) 75 (30)
Max Height Difference m
30 30 30 30
Operation Range Cooling °CDB (Min to Max)
-15 to 46 -15 to 46 -15 to 46 -15 to 46
Operation Range Heating °CDB (Min to Max)
-15 to 24 -15 to 24 -15 to 24 -15 to 24
Refrigerant Type
R410A R410A R410A R410A
Refrigerant Amount g
2,100 3,350 3,350 3,450

Why Choose Fujitsu

5 year warranty logo
Peace of mind

A 5 year parts and labour warranty across the entire domestic range.

Explore now
A brand you can trust

Voted Australia's Most Trusted Air Conditioning Brand (2018-2022)

Explore now
Exceptional after sales service

Access high-level support from our in-house customer care and technical support department.

Explore now
sporting chance logo
Proud sponsors

A percentage of sales from Fujitsu air conditioning units goes to Sporting Chance.

Explore now

Find where to buy Fujitsu General air conditioning

We have a comprehensive network of retailers and dealers right across Australia to ensure that there is a local stockist in your area to assist you wherever you are.

map-icon-white Find a Stockist

Frequently Asked Questions about Cassette 4-way Flow Air Conditioners